Safety Relays Product List

SNO 5002K plus
SNO 4063KM
SNO 4063K
SNO 4062KM
SNO 4062K
SNO 4003K plus
SNA 4064K
SNA 4063K
SNA 4044K
SNA 4043K
SNE 4004KV
SNE 4004K
SNV 4063KL
SNV 4063KP
SNE 4003K
SNZ 4052K plus
SNO 2005

Safety Relay

SNO 5002K plus

Safety relay for emergency stop and guard door applications
SILCL2 in accordance with EN 62061, PL d, Category 3 in accordance with EN ISO 13849-1, in accordance with EN ISO 13849-1, Stop category 0 in accordance with DIN EN 60204-1, Manual or automatic start
With cross circuit detection of the reset inputs, Feedback circuit for external contactor monitoring, 2 enable circuits, NO positively guided, 1 signaling current path, Input debouncing, Error message from SUPPLY-LED

Safety Relay

SNO 4063KM

Base unit for emergency stop and guard door applications
Base unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring.
PL e and category 4 as per EN ISO 13849-1, Stop category 0 as per DIN EN 60204-1, Manual or automatic start, With / without cross short detection, Feedback circuit for external contactor monitoring, 3 enable circuits, NO positively guided, For processing signals from the output signal switching devices (OSSD) of a light curtain, according to DIN EN 61496-1, For post-switching a switching mat according to DIN EN 1760-1 (SNO 4063KM), Input debouncing (SNO 4063KM)

Safety Relay

SNO 4063K

Based devices for emergency stop, safety gate applications,
Basic unit according to DIN EN 60204-1 and EN ISO 13849- 1, for single or dual channel emergency stop monitoring PL e and category 4 according to EN ISO 13849-1, Stop Category 0 according to EN 60204-1, Manual or automatic start, with / without cross monitoring, feedback loop for monitoring external contactors, 3 enabling current paths, contact, positively driven to processing of signals from the output switching elements (OSSD) of a light curtain according to DIN EN 61496-1, for downstream connection to a safety mat in accordance with DIN EN 1760-1 (SNO 4063KM), debounce (SNO 4063KM)

Safety Relay

SNO 4062KM

Basic unit for emergency stop and guard door applications
Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring.
PL e and category 4 as per EN ISO 13849-1, SILCL 3 as per DIN EN 62061, Stop category 0 as per DIN EN 60204-1, Manual or automatic start, With/without cross short detection, Feedback circuit for external contactor monitoring, 2 enable circuits, 1 signal circuit, For processing signals from the output signal switching devices (OSSD) of a light curtain, according to DIN EN 61496-1, For post-switching a switching mat according to DIN EN 1760-1 (SNO 4062KM), Input debouncing (SNO 4062KM)

Safety Relay

SNO 4062K

Basic device for emergency stop and safety door applications, the basic unit according to DIN EN 60204-1 and EN ISO 13849- 1 for single or dual channel emergency stop monitoring, PL e and category 4 according to EN ISO 13849-1, SILCL 3 according to DIN EN 62061 stop category 0 according to EN 60204-1, Manual or automatic start, with / without cross monitoring, feedback loop for monitoring external contactors, 2 enabling current paths, 1 signaling current path, for processing signals from the output switching elements (OSSD) of a light grid according to DIN EN 61496-1, for downstream connection to a safety mat in accordance with DIN EN 1760-1 (SNO 4062 KM), debounce (SNO 4062 KM)

Safety Relay

SNO 4003K plus

The unit is designed for single or twin channel control as a contact expansion.
SNE 4003K with screw terminals, fixed
PL e and category 4 as per EN ISO 13849-1, SILCL3 as per EN 62061, Stop category 0 and 1 DIN EN 60204-1
Safe insulation as per DIN EN 50178, Single or twin channel control, 1 feedback current path (NC), 3 enable current paths (NO), 1 signal current path (NC), Suitable for semiconductor control

Safety Relay

SNA 4064K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNA 4063K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNA 4044K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Saftey Relay

SNA 4043K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNE 4004KV

Extension unit for safety switchgear
Expansion unit as per EN 60204-1 and EN ISO 13849-1; PL e and category 4 as per EN ISO 13849-1; SILCL3 as per EN 62061; Single or twin channel control; 4 enable circuits; 2 signal circuits; 1 feedback circuit; With fall-back delay and time buffering (SNE 4004KV)

Safety Relay

SNE 4004K

Extension unit for safety switchgear
Expansion unit as per EN 60204-1 and EN ISO 13849-1, PL e and category 4 as per EN ISO 13849-1, SILCL3 as per EN 62061, Single or twin channel control, 4 enable circuits, 2 signal circuits, 1 feedback circuit, With fall-back delay and time buffering (SNE 4004KV)

Safety Relay

SNV 4063KL

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4/3 and stop category 0/1, Single or twin channel control via contacts or semi-conductors, Cross short detection, simultaneity monitoring
Reset button monitor, 3 release current circuits (2 without delay, 1 fallback delayed)

Safety Relay

SNV 4063KP

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4/3 and stop category 0/1, Single or twin channel control via contacts or semi-conductors, Cross short detection, simultaneity monitoring
Reset button monitor, 3 release current circuits (2 without delay, 1 fallback delayed)

Safety Relay

SNE 4003K

Relay output extension for safety switching devices; with single or two-channel control; by contacts or semiconductors; Input voltage range DC 15 - 30 V; Stop category 0 and 1 according to EN 60204-1; Application up to safety category 4 according to EN 954-1; Safe isolation according to EN 50178; Contact equipment, positive action: 3 NO (shares), 2 NC contacts (signaling contacts); Rated voltage: 24 V DC; Connectivity Technology (specify when ordering): fixed screw, screw plug; Mounting: DIN rail; Width: 22.5 mm;

Safety Relay

SNZ 4052K plus

Safety relay for two-hand module (EN 574, TYPE IIIC)
in accordance with EN 62061 to SILCL3, in accordance with EN ISO 13849-1 to PL e and Category 4, Cross short detection for input circuits, Feedback circuit for external contactor monitoring, 2 release current circuits, NO contact positively guided, 1 signal generator current circuit, Error message from SUPPLY LED

Safety Relay

SNO 2005

Basic unit for emergency stop and guard door applications
Basi unit as per DIN EN 60204-1 and EN ISO 13849-1, PL e / category 4 as per EN ISO 13849-1, Stop category 0 as per DIN EN 60204-1, SILCL 3 as per DIN EN 62061, Cross-over detection with feedback circuit for monitoring external contactors, One or twin channel emergency stop or guard door monitoring, 3 enable circuits, 1 signal circuit